2R-6
Introduction:

Ultra Low Insertion Loss
Size: 6.2*4.2mm
Impluse Spark-over Voltage:075-3000V
5KA surge capability tested with 8/20μs pulse as defined by IEC 61000-4-5
Excellent response to fast-rising transients

Part Number 100V/s(V) 1KV/μs(V) 8/20μs,10times(V) 50Hz,1sec(A) 10/1000μs,100A(times) test voltage DC(V) (GΩ) Capacitance(pF)
2RL075M-6 75±20% 700 5 5 500 25 1 1.0
2RL090M-6 90±20% 700 5 5 500 50 1 1.0
2RL145M-6 145±20% 700 5 5 500 100 1 1.0
2RL150M-6 150±20% 700 5 5 500 100 1 1.0
2RL230M-6 230±20% 650 5 5 500 100 1 1.0
2RL250M-6 250±20% 650 5 5 500 100 1 1.0
2RL300M-6 300±20% 700 5 5 500 100 1 1.0
2RL350M-6 350±20% 750 5 5 500 100 1 1.0
2RL400M-6 400±20% 800 5 5 500 100 1 1.0
2RL470M-6 470±20% 900 5 5 500 250 1 1.0
2RL600M-6 600±20% 1000 5 5 500 250 1 1.0
2RL800M-6 800±20% 1200 5 5 500 250 1 1.0
2RK1000M-6 1000±20% 1600 3 3 300 500 1 1.0
2RK1200M-6 1200±20% 1800 3 3 300 500 1 1.0
2RK1800M-6 1800±20% 2600 3 3 300 500 1 1.0